Voltmat Power
| Product Name | DC Switching Power Supply | Operating Relative Humidity | 20%~88% |
| Power Rating | 3000W | Application Scenarios | Power electronics, electroplating, water treatment, battery charging, new energy maintenance, etc. |
| Input Voltage | Single-phase/Three-phase 220V±10% 50-60HZ / 110V±10% 50-60HZ / 380V±10% 50-60HZ |
Protection Functions | Overcurrent, overvoltage, overheating, short-circuit protection |
| Output Voltage | 12V, 15V, 24V, 30V, 36V, 48V, 50V, 60V, 72V, 80V, 90V, 110V, 150V, 220V, 300V, 400V, 500V, 600V, 700V, 800V, 1000V | Product Features | High stability, high reliability |
| Output Current | Power ÷ Output Voltage (calculated based on selection) | Warranty Period | 1 Year |
| Power Conversion Type | AC-DC | Product Weight | Approximately 10KG |
| Efficiency | ≥88-89% | Carton Dimensions | 530x295x240mm |
| Output Voltage Accuracy | ±1% | - | - |
Before powering on, inspect the device for any damage during transit, such as loose screws, physical abnormalities, shaken-off terminal wires, or moisture issues. Address any issues before proceeding.
For safety, add an external air switch at the power input terminal to control input power. Connect the ground wire and input power wires properly according to the rear panel labels. Confirm the input supply voltage matches the specifications in this manual.
The cooling fan is temperature-controlled and will start automatically when internal temperatures exceed the threshold. Fan speed dynamically adjusts with output load. Do not block the air inlets and outlets.
When the internal temperature reaches the overheating threshold, the machine stops working for protection. It will auto-resume normal operation once the internal temperature drops.
Avoid placing the device in environments with severe vibration, humidity, direct sunlight, rain, or high concentration of corrosive gases and dust particles.
Regular dust removal (using dry compressed air) can significantly increase device service life. Do not open the external casing without professional guidance, due to high internal voltages.
If the device is idle for more than 6 months, store it in a dry, ventilated room and power it on for at least 30 minutes to maintain component longevity.
Warning: Only connect to your load equipment after performing a normal power-on test without errors.
If any abnormal operation occurs, switch off the input power immediately. Verify all wiring, screws, switches, and settings. If issues persist, please notify support promptly to resolve the problem. Do not perform unauthorized disassembly.
A: Yes, it features comprehensive protection, including overcurrent, overvoltage, overheating, and short circuit safety shutdowns.
A: Yes, reverse polarity protection can be customized and added upon request.
A: For continuous, long-term operation, it is recommended to design the system with extra capacity and utilize the power supply below 80% of its rated capacity.
A: Yes, adjusting settings is highly convenient. Both parameters can be precisely configured via dual control knobs on the front panel.
A: Yes, this unit features a fully isolated design to ensure safe and stable operation.
A: The output voltage regulation starts from 1V up to the maximum rated voltage capacity.